4 min read

As a leading provider of alarm management software, TiPS Incorporated is proud to introduce the Capture 8.1.0 release—our latest qualified version designed to future-proof your alarm system integration. This update enhances Capture’s ability to meet evolving connectivity demands while delivering improved security and reliability across your operations.

What is LogMate Capture and Signal

Capture is a core component of the LogMate® product suite, designed to collect alarm and event data from a wide variety of host systems. It interfaces with these systems via ports and processes the data into a Microsoft SQL Server database, serving as a central repository for alarm and event information. This setup enables organizations to monitor and analyze their systems effectively, supporting operational decision-making and compliance requirements. Capture’s integration with LogMate® ensures that alarm management information is consolidated and presented in a meaningful context, enhancing situational awareness and response capabilities. Additionally, the High Availability module allows multiple redundant Capture installations to connect to a highly available SQL Server Cluster, ensuring data reliability and system resilience.

The Signal application is a real-time event detection and response engine that monitors the alarm and event messages collected by the Capture module. When specific conditions are met, Signal automatically triggers predefined actions such as sending notifications, updating logs, or initiating corrective processes. This automation enhances operational efficiency by reducing manual intervention and ensuring timely responses to critical events. As part of the LogMate® suite, Signal integrates seamlessly with other modules, providing a comprehensive solution for alarm management and event analysis.

What’s New in Capture 8.1.0

We’re excited to announce a new release of the LogMate Capture that includes important new features, performance improvements, and critical bug fixes. As always, our goal is to ensure greater reliability, broader compatibility, and more control for users managing industrial alarm and event data.

New Features in Capture 8.1.0

This release introduces a range of enhancements designed to improve platform compatibility, configuration flexibility, and performance:

  • Platform Qualification: Capture and Signal are now qualified for Microsoft Windows Server 2022 and SQL Server 2022.

  • Improved SCADA Integration: AVEVA Plant SCADA (ClearSCADA) OLE Ports can now use a join table when querying from the source database.

  • Millisecond Epoch Support: Capture can now process Epoch time values that include milliseconds.

  • Connection Handling Enhancements:

    • A new AsyncConnectionOpener allows better timeout control when connections fail between Capture and database servers.

    • Capture now supports a cancellation token to ensure smooth shutdowns even during connectivity issues.

  • Grace Period Extension: The maximum grace period for invalid TiPS license key reads has been increased to 24 hours.

  • SQL Flexibility: Removed previously hardcoded limitations for SQL Server connection types.

  • Expanded Siemens WinCC Support:

    • Added Siemens WinCC as an ASCII import option.

    • Capture can now skip ASCII checksums at the end of WinCC files by enabling the SkipCheckSum=1 setting in the TiPS.ini file.

  • Signal Enhancements: Signal’s Simple Event Detection now allows the Port field to be used in LMFW table mappings.

 

Bug Fixes

We’ve resolved several critical and long-standing bugs to improve data integrity, system stability, and ease of use:

  • Security: Resolved the Microsoft Windows Unquoted Service Path Enumeration Vulnerability in Capture and Signal services.

  • Data Handling:

    • Fixed a startup bug that caused data loss in .dat file processing due to mismatched columns.

    • Corrected a race condition that previously caused early data processing before the LogMate Database Definition was fully initialized.

    • Prevented .dat file overwriting when errors were present in the target database.

  • Stability Improvements:

    • Addressed a bug causing Capture to hang on shutdown due to infinite loops in the DBthread.

    • Fixed OLE Port shutdown behavior when “Stay Connected to Datasource” was enabled.

    • Resolved buffer overflow issues that could stall TCP server ports.

    • Fixed a condition where long ASCII filenames and checksum anomalies caused instability.

  • Performance and Control:

    • Reduced port deactivation time by adding SQL command and connection timeouts.

    • Ensured trigger recreation for LMFW tables works as expected during reinitialization.

    • Improved detection for incomplete ASCII files during checksum validation.

 

System Requirements

To ensure optimal performance and stability, Capture 8.1 has specific system requirements. Below are the necessary configurations:

Operating Systems Supported:

  • Windows Server 2022, 2019, 2016
  • Windows 11 and Windows 10

Database Compatibility:

  • SQL Server 2022, 2019, 2017, 2016

    Known Limitations

    While this release brings many improvements, a few limitations remain that users should be aware of:

    • Archiving Restrictions: Archiving SQL data to ASCII text is only supported on 32-bit systems running LogMate Capture with local SQL Express.

    • Tag Concatenation Limits: The $$Tag concatenation feature is limited to UsrStr fields 1–20.

    • ASCII Port Constraints:

      • File paths (including filenames) are limited to 256 characters.

      • Remote file shares do not automatically recover from credential changes without restarting Capture.

    • Notification Limitations: Signal running as a service does not trigger GUI-based events like svcMssg or Calculator-based actions.

    • User Permissions: Capture does not alert users when run under a non-administrator account, which may cause data update failures.

    • DB Connection Reliability: Capture may not start reliably when using IP addresses in connection strings if DNS is unavailable. Hostname mapping is recommended.

    Mitigation and Support: We’re committed to resolving these limitations and enhancing the functionality of TiPSView. Should you encounter any issues or require assistance, please don’t hesitate to contact our support team.

     

    How to Request the Upgrade

    Interested in upgrading to the latest version? Simply contact our TiPS Sales Team to request your download link for Capture 8.1. Please note that an active ESS support agreement is required to access this release at no additional cost.

    The upgrade process is quick and typically takes only a few minutes to complete. Our Support Team will also share best practices and guidance to ensure a smooth and successful deployment.